←
工程 Markdown
(已压缩)MGW6-1600
已按原始 PDF 重建 7 页 · 6 页需重点核对
待完善
修改记录
隐藏 PDF
编辑
预览
更改已保存
# (已压缩)MGW6-1600 <!-- source-page:1 --> ACB Air Circuit Breaker Committed to becoming a world-class manufacturer of intelligent electric https://www.maxge.com <!-- source-page:2 --> Internal Structure 1 Face Body Drawer base Intelligent controller Shunt release 1 2 3 4 5 Closing electromagnet Under-voltage release Arc chamber Secondary terminals Moving contact 6 7 8 9 10 Auxiliary switch Fixed contact Electric operating mechanism Energy storage mechanism Handle crank 11 12 13 14 15 02 Intelligence beyond vision 5 4 15 DRAW-OUT CIRCUIT BREAKER 7 6 2 14 8 9 10 11 12 3 13 <!-- source-page:3 --> Intelligent Controller Characteristics MGA6-2M MGA6-3M MGA6-3H √ √ √ √ √ √ √ √ O O O O — √ O √ √ √ √ √ √ √ √ O O O O — √ O — — — — — — — √ O — — — — √ — Undervoltage protection (Off by default) Voltage unbalance protection (Off by default) Overfrequency protection (Off by default) Underfrequency protection (Off by default) Phase-sequence protection (Off by default) Reverse power protection (Off by default) Required current protection (Off by default) Load monitoring Zone interlocking Voltage-checking protection Overload reopening Generatrix/contact temperature protection Time-phased required current protection Thermal memory Payment (payment reminder) management Protection functions Three-phase current, maximum of instantaneous value, unbalance rate Ground/leakage current √ √ √ Current √ O √ O √ O Neutral current Voltage: Line voltage, Phase voltage,average voltage, unbalance rate √ √ — √ √ √ √ √ √ √ √ — — — — Frequency Power: active power Power: reactive power, apparent power Power factor Measurement functions Electrical energy: active electrical energy, reactive electrical energy, apparent electrical energy Phase-sequence Waveform capture Harmonic measurement System clock Long time delay heat capacity Self-test function: overtemperature of controller, memory fault, A/D sampling √ √ — √ √ O √ √ √ √ O √ √ — — — — — √ √ √ √ √ — O O √ √ 10 times √ 10 times √ 10 times √ — √ √ — O O √ √ 10 times √ 10 times √ 10 times O — √ — — O O — √ 10 times — — O O Test function Button lock function Replacement with electricity Remote reset I/O faultily tripping function Contact wear rate Tripping records Alarm records Historic records Replacement records Quad programmble contact output Hand-held programmer interface Maintenance functions Contact output Data interface Notice: “√” means basic function; “O” means optional function; “ ”means no such function 04 Intelligence beyond vision <!-- source-page:4 --> Enterprise code Air circuit breaker Design code Frame Size Number of pole MG - / W 6 □ □ Synopsis Of Structure External Structure 01 Intelligence beyond vision MG W 6 1600A,2000A,3200A,4000A,6300A,7500A 3P,4P Reset button/Fault tripping indication Breaking button Closing button Manual energy storage Energy storage/Energy release indication Breaking and closing indication Face Unlock button Nameplate Handle drive position Three position indication Handle storage position Intelligent controller <!-- source-page:5 --> Intelligent Controller Characteristics MGA6-2M MGA6-3M MGA6-3H Intelligent trip unit 智能控制器 3M Intelligent trip unit 智能控制器 3H In= In= In= Intelligent trip unit 智能控制器 2M Picture of product 设置 set 返回 reset 设置 set 返回 reset 设置 set 返回 reset 确定 enter 确定 enter 确定 enter 查询 check 查询 check 查询 check 复位 复位 复位 TEST TEST TEST 运行 运行 Run Run 报警 报警 状态 Alarm Alarm Status 通信 BUS AP AP Ii 200,400,630,800,1000,1250,1600 O O Frame 1600 O 630,800,1000,1250,1600,2000 O O O Frame 2000 Rated current 1600,2000,2500,2900,3000,3200 O O O Frame 3200 O O 2000,2500,2900,3000,3200,3600,4000 O Frame 4000 O O 4000,5000,6300 O Frame 6300 5000,6300,7500 O O O Frame 7500 220V AC 380V AC 90-300V DC 50VAC (70V DC) ~480V AC (650V DC) AC200-AC450 universal use 24V DC 48V DC Other voltage can be customized LED current column Nixie+LED Display Segment LCD Chinese dot-matrix LCD+LED Button Operation Rotary switch + button Language:Chinese/button Modbus-RTU Profibus-DP HPLC (DL/T 645) wifi Device NET CAN Ethernet Profi NET IEC61850 Bluetooth 4G-LTE Overload Long time delay (Ir) (Multiple curves are available) Short-circuit short time delay (Isd) Short-circuit instantaneous (li) Current unbalance protection Residual ground fault protection O O O O O O O O — — — √ √ — √ √ O O O O O O O O O O √ √ √ √ O O O O O O O O — — — √ √ — √ — — — — — — — — — — — √ √ √ √ O O O O O O O O — √ — — √ — √ — — — — — — — — — — — √ √ √ √ Auxiliary power supply voltage Human-computer interface Communication functions Residual ground fault protection by default Residual current protection (I△n) Neutral line overcurrent protection (3P+N, 4P) Overload pre-alarm Making Current Release (MCR) Out-of-limit tripping protection (HSISC) Overvoltage protection (Off by default) Zero sequence ground-fault protection Ground fault protection (Ig) √ √ √ Protection functions O O √ √ √ √ O O √ √ √ √ O O — O O — 03 Intelligence beyond vision <!-- source-page:6 --> Ratings and Specifications Frame Size Characteristics Frame size rated current In(A) Number of poles Rated current In(A) Rated voltage Ue(V) Insulation voltage Ui(V) Impulse withstand voltage Uimp(V) Rated current of N-pole In(A) Ultimate breaking capacity Icu(kA) 380/400/415/440 Operation breaking capacity Ics(kA) Short-time withstand current (1s) RMS Icw(kA) Max total tripping time(ms) without time delay Closing time(ms) Characteristics Mechanical life Maintenance free Closing time(ms) Connection mode Overall dimension H(height)XW(width)XL(thickness) 50/60Hz AC 380V, 400V, 415V, 440V 380/400/415/440 380/400/415/440 Electrical life Maintenance required Fixed type 3P Fixed type 4P Drawout type 3P Drawout type 4P MGW6-1600 1600 3,4 200,400,630,800, 1000,1250,1600 1000V 12 50%/100%In 66 66 55 12-18 60(max) MGW6-1600 8000 15000 30000 Horizontal 310X263X199 310X333X199 345X275X297 345X345X297 <!-- source-page:7 --> Overall and Mounting Dimensions MGW6-1600 MGW6-1600/200A-1600A ACB Fixed Type Door frame center line 258 128 8-Φ5 Door frame center line 199 220 233(3P) 116.5 303(4P) 211 285 310 107 33 T 322 280.5 275 142.5 161 59 100 ACB mounting base 121 131.5 Mounting hole pitch 242(3P)312(4P) 263(3P)333(4P) MGW6-1600 ACB Fixed type(3P,4P) 242(3P) 312(4P) Rated current In(A) Dimensions T(mm) 25 50 200,400,630,800,1000 10 15 32.5 1250,1600 18 70 70 70 Mounting dimensions Horizontal wiring MGW6-1600/200A-1600A ACB Drawout Type Door frame center line 297 258 129 Door frame center line 220 272 324(4P)254(3P) 10-Φ5 127 Separation position 211 41 120 118.5 118.5 275 316 345 60 68 T 321 107 34 2 210 230 35 29 10 ACB mounting base 137.5 345(4P)275(3P) 95 Mounting hole pitch MGW6-1600 ACB Drawout type(3P,4P) 50 25 32.5 15 Rated current In(A) Dimensions T(mm) 70 70 70 400,630,800,1000 10 Horizontal wiring 1250,1600 18 Mounting dimensions
编辑:(已压缩)MGW6-1600 · MAXGE Markdown 工作台