工程 Markdown
iSGM6E-630
已按原始 PDF 重建 5 页 · 4 页需重点核对
待完善
修改记录
隐藏 PDF
编辑
预览
更改已保存
# iSGM6E-630 <!-- source-page:1 --> Electronic Type With LCD iSGM6E Moulded Case Circuit Breaker 20 <!-- source-page:2 --> Ratings And Specifications Frame Size Model Number of poles Rated current(A) In Standard Reference temperature Rated operational voltage Rated impluse withstand 8 (Icw) Breaking capacity level breaking capacity Icu(kA) breaking capacity Ics(kA) lcu=Ics(kA) Mechanical Endurance Electrical Endurance Accessories M H 85 60 75 60 75 Electronic Type With LCD B Alarm switch(SD) Shunt tirp(MX) AC Motor Mechanism 22 <!-- source-page:3 --> Product Dimension Drawing iSGM6E iSGM6E Frame Size Length Width Height Length Width Height 23 Overload Operation TEST DC12V BACK OK USB In=1600A iSGM6E Dimensions mm(L×W×H) Electronic Type With LCD Overload Operation TEST DC12V BACK OK USB In=1600A 630 257 257 <!-- source-page:4 --> Setting Parameters Electronic Type With LCD iSGM6E-630A Frame Size Rated current In(A) 250 300 315 320 400 500 600 630 Ir(A) Long Delay Current Setting 160-400A in steps of 1A 100-250A in steps of 1A 120-300A in steps of 1A 126-315A in steps of 1A 128-320A in steps of 1A 200-500A in steps of 1A 240-600A in steps of 1A 252-630A in steps of 1A tr(S) Long Delay Time 12-150sec in steps of 1 sec+OFF Isd(A) Short Circuit Protection Of Low Level Faults 252-3780A in steps of 1A 256-3840A in steps of 1A 400-6000A in steps of 1A 480-7200A in steps of 1A 504-7560A in steps of 1A 200-3000A in steps of 1A 240-3600A in steps of 1A 320-4800A in steps of 1A tsd (S) short time 0.06-1sec in steps of 0.01 sec+OFF Ii(A) Short Circuit Protection Of High level Faults 400-3500A in steps of 1A + OFF 480-4200A in steps of 1A + OFF 504-4410A in steps of 1A + OFF 512-4480A in steps of 1A + OFF 800-7000A in steps of 1A + OFF 960-8400A in steps of 1A + OFF 1008- 8820A in steps of 1A + OFF 640-5600A in steps of 1A + OFF Ip(A) Pre Trip Alarm Setting Multiple 70-250A in steps of 1A 84-300A in steps of 1A 88.2-315A in steps of 1A 89.6-320A in steps of 1A 140-500A in steps of 1A 168-600A in steps of 1A 176.4-630A in steps of 1A 112-400A in steps of 1A For 4p Ig(A) Ground Fault Pickup Current 50-250A in steps of 1A + OFF 60-300A in steps of 1A + OFF 63-315A in steps of 1A + OFF 64-320A in steps of 1A + OFF 100-500A in steps of 1A + OFF 120-600A in steps of 1A + OFF 126-630A in steps of 1A + OFF 80-400A in steps of 1A + OFF For 4p tg(S) Ground Fault Pickup Time 0.4-1sec in steps of 0.1sec <!-- source-page:5 --> MCCB With Spreader Link Dimensions Front connection Note:All dimensions are in mm SGM6/6s/6sm/6E-400A/630A 3 POLES & 4 POLES 343 150 60.5 60.5 197 32.5 20 32.5 48 48 311 194 194 257 257 224 16 44 26 26 26 28 44 14.3 44 48 108 110.5 98 43.5 38/40 152 6
编辑:iSGM6E-630 · MAXGE Markdown 工作台