# SGV2-II-32-SGV3-I1-80 Series <!-- source-page:1 --> MAXGE SGV2-II-32/SGV3-II-80 Series 卜 Motor protection circuit breaker Standard IEC60947-1 Rated insulation voltage Ui(V) 690 Rated impulse withstand voltage Uimp(kV) 6 Rated operating voltage Ue(V) 380/400/415V~ Rated frequency(Hz) 50/60 Frame rated current Inm(A) 32A.80A Starter installation CategoriesI Degree of Protection IP20 Ambient air temperature(C) -5 to +40,max.90% humidity Storage temperature(℃) -40~+70 Maximum operating altitude(meters) ≤2000 Certification CE CB BCV3-1-10 MAXGE MAXGE SGV2-I1-32 SGV2-II-32 SGV3-II-80 <!-- source-page:2 --> MAXGE SGV2-II-32/SGV3-II-80 Series 卜 Motor protection circuit breaker Hot component setting current adjustment range: rated limit and rated operating short-circuit breaking capacity Rated limit short-circuit breaking capability ICU, Fastener Tuning current rated operation short-circuit breaking capability Ics kA Arcing Model rated current In (A) adjustment range(A) 400/415V 690V distance(mm) Icu ICS Icu lcs 0.16 0.1~0.16 100 100 100 100 0.25 0.16~0.25 100 100 100 100 0.4 0.25~0.4 100 100 100 100 0.63 0.4~0.63 100 100 100 100 1 0.63~1 100 100 100 100 1~1.6 100 100 100 100 1.6~2.5 100 100 3333 2.25 SGV2-II-32 4 2.5~4 100 100 2.25 40 4~6.3 100 100 2.25 6~10 100 100 2.25 9~14 7s 333 2.25 13~18 2.25 17~23 666 2.25 20~25 3 2.25 24~32 3 2.25 20~25 17.5 4 2.25 23~32 17.5 4 2 SGV3-II-80 30~40 17.5 4 2 50 37~50 17.5 48~65 17.5 44 222 63~80 17.5 4 The standard rated power of the three-phase motor controlled by the circuit breaker Standard rated power of three-phase motor(kw) Fastener Tuning current Model AC-3,50Hz/60Hz rated current In (A) adjustment range(A) 230/240V 400V 415V 440V 500V 690V 0.16 0.1~0.16 0.25 0.16~0.25 0.4 0.25~0.4 0.63 0.4~0.63 0.37 1 0.63~1 0.37 0.37 0.55 1.6 1~1.6 0.37 0.55 0.75 SGV2-II-32 2.5 1.6~2.5 0.37 0.75 0.75 15 1.1 15 4 2.5~4 0.75 1.5 15 2.2 4~6.3 1.1 2.2 3 3.7 34 6~10 2.2 4 4 4 5.5 9~14 3-4 5.5 7.5 7.5 13~18 17~23 5.5 20~25 5.5 911巧1 9什 18.5 24~32 7.5 18.5 25 20~25 18.5 23~32 15 15 30~40 18.5 18.5 SGV3-II-80 37~50 48~65 63~80 23 37 <!-- source-page:3 --> MAXGE SGV2-II-32/SGV3-II-80 Series Motor protection circuit breaker The operating performance of the circuit breaker Operation cycle number Model Rack rated current Inm A Hourly operation cycles Electrical life Mechanical Life SGV2-II-32 32 120 10000 100000 SGV3-I-80 80 120 1500 8500 Action characteristics of balanced load of each phase of the circuit breaker (Motor protection) Circuit breaker for protecting electric motor Ambient air Type Setting temperature Serial number current multiple Tripping time Status 1 1.05 2h non-tripping Initial SGV2-I-32 2 1.2 2h tripping SGV3-II-80 Following serial 1 20±2℃ 3 1.5 Action within 2 minutes 4 7.2 2~10s tripping Initial Overall Dimensions 70±0.3 450.32 l 口 口 9O+6 9O+寸一' [o] M 35.5±0.3 37.3±0.3 口口 一 口口 nn 品+ + 品 _mO十9寸寸 ◎ 店 ① ① 口 1 2 90±0.5 121±0.5 SGV2-I-32 SGV3-I-80