# (已压缩)SGBR-40AFD Series <!-- source-page:1 --> OVERLOAD Test current: In:6-40A 1.13 x In No tripping within an hour 1.45 x In Tripping within an hour ARC FAULT Serial Arcing Fault Parallel Arcing Fault Grounding Arc Fault SHORT CIRCUIT B,C Tripping Characteristics B:(3-5) x ln C:(5-10) x ln EARTH LEAKAGE I△n: 10,30,100,300mA Type A & AC AFDD Prevents fires Fits in new and existing installations Switched neutral 4 in 1 protection <!-- source-page:2 --> SGBR-40AFD Series Arc Fault Detection Device | Standard | | IEC/EN 62606,IEC/EN 61009-1 | | --- | --- | --- | | Rated conditional shor-t circuit current(kA) | | 6 | | Rated current(A),ln | | 6,10,16,20,25,32,40 | | Number of poles | | 1P+N | | Rated sensitivity currents(mA),IΔn | | 10,30,100,300 | | Tripping curev | | B,C | | Rated residual non-operating current | | 0.5XIΔn | | Rated impulse withstand voltage Uimp(kV) | | 4 | | Rated voltage(V) | | AC 230/240 | | Ambient temperature (°C) | | -25~+40,Max.95%humidity | | Residual current off time | | ≤0.1s | | Type of trip | Ground fault | Electronic | | | Over current | Thermal-magnetic | | | Arc fault | Serial Arcing Fault,Parallel Arcing Fault,Grounding Arc Fault | | | Power supply failure | Over voltage protection | | Electrical endurance | | 2000 | | Mechanical endurance | | 10000 | | Terminal capacity | | 10mm2 flexible/16mm2 rigid | | Protection degree | | IP20 | | Installation | | 35mm DIN rail | | Certification | | | | SGBR-40AFD | | | <!-- source-page:3 --> SGBR-40AFD Series Arc Fault Detection Device Type AC Type A Rated current(A) IΔn Packing unit C curve B curve C curve B curve SGBR-40AFD-6K/C6/10 6 SGBR-40AFD-6K/B6/10 SGBR-40AFD-6K/C6/10-A SGBR-40AFD-6K/B6/10-A 10 SGBR-40AFD-6K/C10/10 SGBR-40AFD-6K/B10/10 SGBR-40AFD-6K/C10/10-A SGBR-40AFD-6K/B10/10-A 16 SGBR-40AFD-6K/C16/10 SGBR-40AFD-6K/B16/10 SGBR-40AFD-6K/C16/10-A SGBR-40AFD-6K/B16/10-A 10mA 20 SGBR-40AFD-6K/C20/10 SGBR-40AFD-6K/B20/10 SGBR-40AFD-6K/C20/10-A SGBR-40AFD-6K/B20/10-A 25 SGBR-40AFD-6K/C25/10 SGBR-40AFD-6K/B25/10 SGBR-40AFD-6K/C25/10-A SGBR-40AFD-6K/B25/10-A 32 SGBR-40AFD-6K/C32/10 SGBR-40AFD-6K/B32/10 SGBR-40AFD-6K/C32/10-A SGBR-40AFD-6K/B32/10-A 40 SGBR-40AFD-6K/C40/10 SGBR-40AFD-6K/C40/10-A SGBR-40AFD-6K/B40/10-A SGBR-40AFD-6K/B40/10 SGBR-40AFD-6K/C6/30 SGBR-40AFD-6K/B6/30 6 SGBR-40AFD-6K/C6/30-A SGBR-40AFD-6K/B6/30-A SGBR-40AFD-6K/C10/30 SGBR-40AFD-6K/B10/30 10 SGBR-40AFD-6K/C10/30-A SGBR-40AFD-6K/B10/30-A SGBR-40AFD-6K/C16/30 SGBR-40AFD-6K/B16/30 16 SGBR-40AFD-6K/C16/30-A SGBR-40AFD-6K/B16/30-A Type AC 30mA 20 SGBR-40AFD-6K/C20/30 SGBR-40AFD-6K/B20/30 SGBR-40AFD-6K/C20/30-A SGBR-40AFD-6K/B20/30-A 25 SGBR-40AFD-6K/C25/30 SGBR-40AFD-6K/B25/30 SGBR-40AFD-6K/C25/30-A SGBR-40AFD-6K/B25/30-A 32 SGBR-40AFD-6K/C32/30 SGBR-40AFD-6K/B32/30 SGBR-40AFD-6K/C32/30-A SGBR-40AFD-6K/B32/30-A 40 SGBR-40AFD-6K/C40/30 SGBR-40AFD-6K/B40/30 SGBR-40AFD-6K/B40/30-A SGBR-40AFD-6K/C40/30-A 5 SGBR-40AFD-6K/C6/100 SGBR-40AFD-6K/B6/100 SGBR-40AFD-6K/B6/100-A SGBR-40AFD-6K/C6/100-A 6 SGBR-40AFD-6K/C10/100 SGBR-40AFD-6K/B10/100 10 SGBR-40AFD-6K/B10/100-A SGBR-40AFD-6K/C10/100-A SGBR-40AFD-6K/C16/100 SGBR-40AFD-6K/B16/100 16 SGBR-40AFD-6K/B16/100-A SGBR-40AFD-6K/C16/100-A SGBR-40AFD-6K/C20/100 SGBR-40AFD-6K/B20/100 100mA 20 SGBR-40AFD-6K/B20/100-A SGBR-40AFD-6K/C20/100-A SGBR-40AFD-6K/C25/100 SGBR-40AFD-6K/B25/100 25 SGBR-40AFD-6K/B25/100-A SGBR-40AFD-6K/C25/100-A SGBR-40AFD-6K/C32/100 32 SGBR-40AFD-6K/B32/100 SGBR-40AFD-6K/B32/100-A SGBR-40AFD-6K/C32/100-A 40 SGBR-40AFD-6K/C40/100 SGBR-40AFD-6K/B40/100 SGBR-40AFD-6K/B40/100-A SGBR-40AFD-6K/C40/100-A SGBR-40AFD-6K/C6/300 SGBR-40AFD-6K/B6/300 SGBR-40AFD-6K/B6/300-A SGBR-40AFD-6K/C6/300-A 6 SGBR-40AFD-6K/C10/300 SGBR-40AFD-6K/B10/300 SGBR-40AFD-6K/B10/300-A SGBR-40AFD-6K/C10/300-A 10 Type A SGBR-40AFD-6K/C16/300 SGBR-40AFD-6K/B16/300 SGBR-40AFD-6K/B16/300-A SGBR-40AFD-6K/C16/300-A 16 SGBR-40AFD-6K/C20/300 SGBR-40AFD-6K/B20/300 300mA 20 SGBR-40AFD-6K/B20/300-A SGBR-40AFD-6K/C20/300-A SGBR-40AFD-6K/C25/300 SGBR-40AFD-6K/B25/300 25 SGBR-40AFD-6K/B25/300-A SGBR-40AFD-6K/C25/300-A SGBR-40AFD-6K/C32/300 SGBR-40AFD-6K/B32/300 32 SGBR-40AFD-6K/B32/300-A SGBR-40AFD-6K/C32/300-A SGBR-40AFD-6K/C40/300 SGBR-40AFD-6K/B40/300 SGBR-40AFD-6K/B40/300-A SGBR-40AFD-6K/C40/300-A 40 <!-- source-page:4 --> SGBR-40AFD Series Arc Fault Detection Device Curves Breaking time of residual current Max.breaking time In(A) IΔn(A) IΔn 2 IΔn 5 IΔn 5-500A 6-40 0.01,0.03,0.1,0.3 0.1s 0.08s 0.04s 0.04s Wiring (The suitable conductors should be used for connection,see table below for relative parameters) Cross section area s(mm2) Tightening torque(N.m) Rated current In (A) 1 6 1.5 10 1.5 13 2.5 16-20 M5 2.0 M4 1.2 6 25 32 40 4 10 AFDD For The Consumer Unit The 18th edition wiring regulations (BS7671) sets out requirements for electrical installations in the UK, including requirements for protection of persons, livestock & property against the risk from fires that may be generated & propagated in electrical installations. Designers & installers are required to ensure that installations are arranged so that the risk of ignition from high temperatures or electric arc is minimised,Protection requirements include protecting against the risk of fire from insulation faults, arcs & sparks & high temperatures.Installing arc fault detection devices is recommended in the 18th Edition as a method for mitigating the risk from fire in final AC circuits from arc faults. Overall and mounting dimensions SGBR-40AFD
编辑:(已压缩)SGBR-40AFD Series · MAXGE Markdown 工作台